Automatic packaging equipment hero banner

Semi-Automatic Perfume Bottle Collar Pressing Machine for Perfume, Cologne, Body Mist and Essential Oil Bottles

Packaging Equipment Capping Machines Perfume & Fragrance Products
Factory Direct Customizable OEM / ODM Available Video Inspection Available Lifetime Technical Support
CE Certified GMP Design FDA Contact Parts

The Perfume Bottle Collar Pressing Machine presses compatible aluminum decorative collars onto glass bottles after the pump has been secured. Pneumatic operation, pedal control and manual height adjustment support operator-assisted assembly. A size-matched pressing head and adjustable bottle holder position the package for each cycle. Within the perfume production equipment range, this benchtop machine performs collar fitting as a separate packaging operation.

Production Speed (BPM)15-30Air Pressure0.4–0.8 MPa
Machine Frame MaterialSUS304 Stainless Steel FrameDrive TypePneumatic
Capping MethodConstant-Force Pneumatic CappingInstallation TypeBenchtop
Capping PrincipleCollar PressingAutomation LevelSemi-Automatic
Capping Head/Heads1Control SystemPedal
Cap Size Range (Ø=mm)1-80Machine Dimensions(L*W*H)mm310mm*260mm*510mm
Capping Torque Range (Nm)(Adjustable)Machine Weight (kg)13
Pneumatic BrandAirTAC


Product Overview

This semi-automatic machine fits aluminum decorative collars to compatible glass perfume bottles. The operator places the collar over the secured pump assembly, positions the bottle in its holder and activates the pneumatic press through the pedal.

For perfume and fragrance packaging, the collar forms part of the finished bottle’s appearance. Its fit, seating position and surface condition should be assessed with the bottle and pump as a complete package.

The single-head benchtop arrangement uses manual height adjustment and an adjustable bottle holder. Pressing force can be adjusted for the approved collar and package, while the pressing head or mold is matched to the collar size.

The rated production speed is 15–30 bottles per minute. Actual output depends on collar placement, bottle positioning and the operator’s handling sequence.

This machine performs decorative collar pressing after pump attachment. It does not replace perfume-pump crimping or provide the bottle’s primary liquid seal. Collar fitting and closure integrity remain separate packaging requirements.


Machine Configuration

A SUS304 stainless steel frame supports a single pneumatic pressing assembly above the bottle-positioning area. AirTAC pneumatic components provide the supplied actuation, with a pedal used to initiate the pressing cycle.

The pressing head or mold is selected to match the decorative collar. Manual height adjustment positions the working assembly around the bottle and pump, while the adjustable holder supports and locates the package beneath the head.

Pressing force is adjustable. The operating setup combines the selected head, bottle position and force setting to achieve the required collar seating.

The machine is designed for benchtop installation. Operators place collars and load and remove bottles manually. Different collar sizes or profiles may require another pressing head and a revised bottle-holder setup.

The complete bottle, secured pump and collar are used together when preparing a packaging format.


Key Features

  • Pneumatic pressing fits decorative collars after the pump has been secured.
  • A single pressing head provides a dedicated collar-assembly station.
  • Pedal control initiates the supplied pressing cycle.
  • Manual height adjustment accommodates the approved bottle and pump arrangement.
  • An adjustable holder positions the bottle beneath the pressing head.
  • Size-matched heads or molds support different approved collar formats.
  • Adjustable pressing force supports package-specific setup.
  • The benchtop frame provides a compact station for operator-assisted packaging.

Applications

  • Perfume & Fragrance Products


Working Principle

The bottle reaches the collar-pressing station with its pump already secured. The operator places the compatible aluminum collar over the pump assembly and positions the bottle in the adjustable holder.

The pressing head or mold is prepared for the collar size and profile. Manual height adjustment aligns the working assembly with the package, and the pressing force is set for the intended fit.

Pedal activation initiates the pneumatic pressing cycle. The head applies the pressing action to seat the collar around the pump assembly. Bottle support and alignment help maintain the intended relationship between the collar, pump and glass container.

After the cycle has completed and the head is clear, the operator removes the bottle and checks the collar’s seating and appearance.

The next bottle is loaded through the same sequence. Production pace depends on collar presentation, package positioning, cycle operation and finished-bottle handling.

When changing collar format, the appropriate head or mold is installed and the bottle position and pressing setup are reviewed. Representative packages are checked before routine production resumes.

Where the package uses a crimped spray pump, a separate perfume bottle crimping machine performs that attachment before decorative collar fitting.


Suitable Products

Perfume
Cologne
Body Mist
Essential Oil
Aluminum Pump Collars
Glass Perfume Bottles, Spray Pumps and Cosmetic Packaging

Warranty24 MonthsPayment Terms40% T/T Deposit, 60% Balance Before Shipment (Alibaba Trade Assurance Available)
Lead Time15–20 Working DaysPackagingStandard Export Fumigation-Free Wooden Case

After-Sales & Technical Support

🔧 Common Problems

Possible operating symptoms include collars sitting at different heights, uneven seating, visible gaps or a tilted finished appearance. Operators may observe marks on the collar, contact marks on the bottle, distortion of the decorative component or interference with the pump assembly. Bottles may sit inconsistently in the holder or move during pressing. Other observations include irregular head travel, slow return, inconsistent pedal response or audible pneumatic leakage. A change of collar format may also produce a different fit or contact pattern from the previous setup. Record the bottle, pump, collar, pressing head and operating setup when investigating an observation.

🛠 Troubleshooting

Problem: The collar does not seat fully. Possible Cause: Component fit, head profile, working position or pressing force is unsuitable. Recommended Solution: Check the complete package and approved tooling before increasing force.Problem: The collar sits unevenly. Possible Cause: Bottle positioning, collar presentation or head alignment differs from the approved setup. Recommended Solution: Stop the machine and review the holder and head position.Problem: The collar shows marks or deformation. Possible Cause: Deposits, damaged tooling or excessive contact force affects pressing. Recommended Solution: Isolate the equipment before inspecting and cleaning the contact surfaces.Problem: The bottle moves during pressing. Possible Cause: The holder does not provide suitable positioning for the package. Recommended Solution: Review the support arrangement using representative bottles before restarting.Problem: The pressing head contacts the pump. Possible Cause: The tool or clearance does not suit the complete assembly. Recommended Solution: Stop production and review the matched head and package geometry.Problem: Head movement or pedal response becomes irregular. Possible Cause: Air-supply conditions, an obstruction or a pneumatic component fault interrupts operation. Recommended Solution: Stop the machine and arrange inspection through the approved service procedure.

🧼 Cleaning Method

1. Stop production through the approved shutdown procedure. 2. Remove bottles and collars from the working area. 3. Isolate the compressed-air supply before manual access. 4. Release retained pressure through the designated method. 5. Remove the pressing head where the cleaning procedure requires disassembly. 6. Clean the head’s contact surfaces using an approved compatible method. 7. Clean the bottle holder and support area. 8. Remove deposits from accessible frame surfaces. 9. Wipe the pedal exterior through the permitted method. 10. Inspect cleaned surfaces for residue or damage. 11. Dry serviced components according to the approved procedure. 12. Refit the pressing head using the specified attachment method. 13. Complete the required function and package checks before production.

📋 Maintenance

1. Establish the service schedule from the supplied component documentation. 2. Isolate the compressed-air supply before service access. 3. Release retained pressure through the approved procedure. 4. Inspect the pressing head for wear, damage or deposits. 5. Check the head attachment according to the service instructions. 6. Examine the bottle holder for looseness or worn contact surfaces. 7. Inspect manual height-adjustment attachments for deterioration. 8. Check pneumatic tubing and fittings for visible damage. 9. Service AirTAC components according to their identified instructions. 10. Inspect the pedal and its connections through the approved method. 11. Maintain installed air-treatment components where fitted. 12. Check the machine’s bench attachment or restraint. 13. Verify the approved setup with representative packages. 14. Record findings against the affected tool or component.

⚙️ Installation

1. Review the machine instructions and approved package samples. 2. Prepare a stable workbench with suitable operating access. 3. Inspect the delivered machine for visible transport damage. 4. Position the machine using the designated handling method. 5. Secure the assembly according to the installation instructions. 6. Position the pedal for deliberate operation. 7. Connect regulated compressed air according to the pneumatic schedule. 8. Install the pressing head matched to the collar. 9. Prepare the adjustable holder for the glass bottle. 10. Set the working height around the assembled bottle and pump. 11. Check clearance through the pressing movement. 12. Establish the pressing-force setting using representative components. 13. Verify operation through the approved commissioning procedure. 14. Inspect collar seating and the completed package condition. 15. Record the approved format setup before routine production.

🔩 Spare Parts

Collar Pressing Head or Mold — Match the Approved Collar
Pressing Head Retaining Hardware
Bottle Holder or Positioning Fixture — Match the Approved Bottle
Bottle Holder Contact Insert — Where Fitted
Pneumatic Pedal Valve Assembly — Match the Installed Type
AirTAC Cylinder Service Seal Kit — Match the Installed Cylinder
Pneumatic Air Tubing and Connector Set
Height-Adjustment Retaining Parts — Match the Installed Assembly

Why Choose This Machine

  • A focused finishing operation: The machine gives decorative collar fitting its own setup and inspection point after the pump has been attached.
  • Package-specific tooling: A head or mold matched to the collar helps define where the pressing action contacts the component.
  • Adjustable setup: Manual height positioning, the bottle holder and adjustable force allow the station to be prepared around the approved package.
  • Compact installation: The benchtop arrangement fits into an operator-assisted packaging area without requiring a dedicated conveyor connection.
  • Flexible production scheduling: Bottles can be presented individually, supporting work organized around different fragrance batches and packaging formats.
  • Separate appearance checks: Collar seating, alignment and surface condition can be reviewed independently from pump attachment and filling quantity.

Frequently Asked Questions

It presses compatible aluminum decorative collars onto glass perfume bottles after the pump has been secured. The operator places the collar and bottle, then activates the pneumatic cycle through the pedal.
No. Pump attachment is completed before collar pressing. The decorative collar is a separate packaging component, and its installation should not be treated as the primary liquid-sealing operation.
The head or mold is matched to the collar’s size and profile. Provide the bottle, secured pump and collar together so the contact shape, clearance and seating position can be assessed.

Installation Requirements

Provide a stable workbench suitable for the machine and operating task. The machine dimensions are 310 × 260 × 510 mm, with a listed weight of 13 kg. Allow additional space for bottle loading, collar supply, completed-package collection and service access.

Position and secure the machine according to its installation instructions. Place the pedal where it can be operated deliberately without obstructing normal movement.

Provide a regulated compressed-air supply within the specified 0.4–0.8 MPa range. Air consumption and treatment requirements follow the final pneumatic schedule.

Arrange the work area so operators can present bottles through the designated loading position. Keep access to moving components controlled according to the machine’s operating provisions.

Prepare the correct pressing head or mold for each approved collar. Provide representative glass bottles with their pumps secured, together with the production collars.

Allow safe access for manual height adjustment and bottle-holder setup. Changes to tooling or position should follow the approved isolation procedure.

Provide suitable lighting for checking collar seating, alignment and visible surface condition. Place upstream pump-attachment and downstream collection tasks so bottles can be handled without unnecessary transfers.


Technical Buyer's Handbook & Deep Insight

Where the Perfume Bottle Collar Pressing Machine Fits

This machine is a dedicated finishing station for fitting aluminum decorative collars after the perfume pump has been secured. Its distinguishing arrangement combines pneumatic pressing, pedal activation, manual height adjustment and a size-matched head.

The benchtop layout suits an operator-assisted workflow. It keeps collar placement and appearance checks separate from filling and pump attachment.

Select the station around the complete package: glass bottle, attached pump and decorative collar. A collar that looks similar to another may still need a different contact profile or setup.

Keep Collar Fitting Separate from Pump Attachment

The decorative collar is pressed after the primary pump attachment has been completed. It should not be used to compensate for an incorrectly secured pump or an incompatible bottle neck.

Check the incoming package condition before collar fitting. The pressing station needs a correctly assembled bottle and pump so that the collar can seat as intended.

Define the acceptance requirements for each task separately. Pump attachment concerns the closure assembly, while collar fitting also introduces visible alignment and finish requirements.

Prepare a Matched Pressing Head

The pressing head or mold follows the collar’s size and profile. Its contact shape needs to apply the pressing action in the intended area without interfering with projecting pump components.

The stated outer-diameter range is 1–80 mm. The actual package also requires review of collar height, internal clearance and the position of the finished collar.

Provide production components for each important format. Do not rely only on a nominal diameter when ordering tooling.

For multiple formats, identify the heads, holders and setup records needed for each. Tooling availability is part of the production plan rather than an assumption that one head fits everything.

Support the Glass Bottle Correctly

The adjustable holder locates the bottle beneath the pressing head. Bottle shape, base stability and the assembled pump height determine the working setup.

A tall or narrow bottle may need a different positioning arrangement from a broad, stable package. Decorative bottle shapes also deserve their own assessment.

Review the complete load path through the package. The selected force and support should seat the collar without producing unacceptable marks, distortion or glass damage.

Keep the approved holder and height settings with the format record so repeat runs begin from a consistent arrangement.

Set Force Around the Required Collar Fit

Pressing force is adjustable, but the appropriate setting follows the package. More force should not be treated as a general solution to a collar that does not fit.

Start with compatible components and matched tooling, then establish the operating setup through representative trials. Check the final position and visible condition of the assembly.

If the collar sits unevenly, investigate alignment, component fit and tooling before increasing force. A change in collar or bottle supplier may require renewed evaluation.

Plan the Operator Cycle at 15–30 Bottles per Minute

The rated speed range includes a repetitive manual task: placing the collar, locating the bottle, activating the cycle and removing the finished package.

Arrange component supply and collection around that sequence. A convenient workstation can reduce unnecessary handling without changing the machine’s pressing function.

Include checks, format changes and replenishment when planning daily output. The rated cycle range alone does not establish sustained production across every package.

The pedal should be positioned for deliberate operation, with the operator following the designated loading and working procedure.

Coordinate the Station with Perfume Filling

The ten-head rotary vacuum perfume filler provides one upstream filling direction for compatible glass bottles.

The four-head magnetic-pump liquid filler provides another dispensing arrangement. Neither filling method independently determines the required pump attachment or collar tooling.

Match the stations by the actual package and operating schedule. Filling, pump attachment and collar pressing are separate duties, even when they share one production area.

Distinguish Collar Pressing from Screw Capping

The servo four-wheel screw capper performs rotational tightening on compatible threaded closures. This collar press applies a pressing action to a separate decorative component.

Selection pointThis collar pressScrew-capping equipment
Main operationPress a decorative collar onto the assembled packageTighten a compatible threaded closure
Working toolSize-matched pressing head or moldThe selected screw-tightening mechanism
Setup focusPosition, support and pressing forceThread engagement, support and tightening settings
Package assessmentCollar seating and finished appearanceCompleted threaded-closure condition

The two operations should not be grouped under a general torque-capping description. Select each machine for the attachment method required by the package.

Maintain Tooling and Bottle-Contact Surfaces

The pressing head and bottle holder contact the package directly. Deposits, damage or an incorrect head can affect the appearance of the collar or bottle.

Inspect these surfaces during routine setup and follow the approved cleaning method. Do not use an abrasive or chemical treatment that damages the contact tool.

The article on moisture in compressed-air systems provides related utility context. The installed pneumatic components determine the required service conditions.

Keep replacement heads and format parts identified by the actual package. A general collar diameter is not always enough to select the correct replacement.

Evaluate Cost Beyond the Benchtop Machine

Include tooling for each format, compressed-air supply, operator handling and the connection with upstream packaging tasks.

The machinery total cost of ownership guide provides a broader purchasing framework. For this station, practical value depends on a suitable tool and repeatable package presentation as much as the press itself.

Prepare the Purchase Specification

  • Provide glass bottles with the intended pumps already secured.
  • Supply the actual aluminum decorative collars.
  • Define the required seating position and finished appearance.
  • Identify the pressing head or mold for each format.
  • Confirm bottle-holder support and manual height adjustment.
  • Agree the force setup and package checks.
  • Plan the workbench, pedal location and compressed-air service.
  • Define component supply and finished-bottle collection.

StriversMachinery evaluates packaging configurations around the actual bottle and component set. The collar-pressing arrangement is prepared for the intended fit, appearance and production workflow.


Ready to Get a Quote?

Contact our team directly for pricing, customization options, and delivery timelines.

💬 WhatsApp Us Now
This field is required.
This field is required.
If you are not sure, just tell us what products do you produce.
This field is required.
Please check the box to confirm you agree to our Privacy Policy and Cookie Policy before submitting.