Industrial vacuum emulsifying mixers for cosmetic cream, lotion, ointment, and pharmaceutical manufacturing applications.

300L Vacuum Mayonnaise Emulsifying Machine with 3-Stage Inline Homogenizer & Oil Water Tanks for Salad Dressing, Ketchup & Sauce Processing

Vacuum Emulsifying Mixers Sauce, Condiment & Food Paste
Factory Direct Customizable OEM / ODM Available Video Inspection Available Lifetime Technical Support
CE Certified GMP Design FDA Contact Parts

The 300L Vacuum Mayonnaise Emulsifying Machine is a fixed-head batch system for compatible mayonnaise, salad dressing, ketchup and sauce formulations. It combines scraped vessel agitation with a standard circulation lobe pump and three-stage inline homogenizer. Within the vacuum emulsifying mixers range, this model provides separate phase preparation, thermal processing and a defined external emulsification circuit under PLC/HMI control.

  • Conical Bottom, Lobe Rotor Pump & Circulation Pipeline for High Viscosity Food Emulsions
Total Capacity (L)360Vacuum Pump BrandHigh-quality domestic/joint venture brands
Working Capacity (L)300Discharge MethodBottom Valve Discharge (Optional Rotor Pump)
Min Batch Size (L)100Discharge ValvesFlush Bottom Valve
Structure TypeTriple Layer (with Jacket & Insulation)Mechanical Seal BrandSingle Mechanical Seal (John Crane/EagleBurgmann Optional) / Double Mechanical Seal (EagleBurgmann)
Contact MaterialSUS304 Stainless SteelTypes of Upper HeadsTorispherical (Dish) Head / Fixed Top Head
Non-contact MaterialSUS304 Stainless SteelTop Openings & AccessoriesVacuum Port / Vacuum Feeding Port / Powder Feeding Port / Liquid Inlet / Fragrance Addition Port / Manway / Sight Glass with Wiper / LED Inspection Light / CIP Spray Ball / Vent Filter / Vacuum Gauge / Pressure Sensor / Compressed Air Inlet
Surface FinishInterior Mirror Polish (Ra ≤ 0.4 μm) & Exterior Satin/Matte FinishMotor BrandSEW / ABB / Siemens / Top-Tier Chinese Brands (Optional)
Jacket Design Pressure (MPa)0.3vem_electrical_componentsSchneider / Siemens / Omron (Optional/Customizable)
Main Tank Mixer TypeGate Agitator + Single/Dual Fixed PaddlesOil & Water PotEquipped with Integrated Oil & Water Pre-treatment Pots
Mixing Speed (rpm)0–63 rpmOil & Water Pot Capacity (L)Oil: 150 L / Water: 240 L
Mixing Motor Power (kW)4Explosion ProofStandard Non-Explosion Proof (For Regular Cosmetics)
Frequency ControlVariable Speed with VFD (Delta, Siemens, ABB, Schneider, Optional)Platform & LadderSUS Anti-slip Platform with Guardrails & Ladder
Scraper SystemWall-Scraping PTFE ScrapersVoltageConfigurable to local grid (110V–480V, 50/60Hz, Single or 3-Phase)
Homogenizer PositionExternal Inline Recirculating HomogenizerTotal Power (kW)22
Homogenizer TypeMulti-Stage High Shear MixerAir Pressure0.4–0.8 MPa
Homogenizer Power (kW)15Drive TypeElectro-Pneumatic Combined
Homogenizer Speed (rpm)0–3000 rpm (Variable Speed)Installation TypePlatform-mounted
Max Processing Viscosity (mPa·s / cP)50,000Automation LevelFully Automatic
Heating MethodElectric Heating via Jacket / External Steam Heating (Optional)Control SystemPLC + HMI Touch Screen Control
Cooling SystemTap Water / Cooling Tower Circulation (Chilled Water / Glycol Circulation Optional)PLC SystemSiemens
Water ChillerExternal Water Chiller Unit (Optional)HMI / Touch ScreenSiemens
Temperature Control Accuracy±1°CMachine Dimensions(L*W*H)mm2100*1500*2200
Vacuum Degree (MPa)-0.09Machine Weight (kg)1500


Product Video


Product Overview

This machine provides a coordinated preparation platform for compatible food emulsions and sauces. Its main vessel combines gate agitation, PTFE wall scraping, vacuum provision and a heating-and-cooling jacket. Separate oil and water pots support formulation-specific ingredient preparation before transfer into the main batch.

For mayonnaise, salad dressing and sauce processing, the external circuit gives the product a defined route through the inline homogenizer. A standard lobe rotor pump draws material from the conical-bottom vessel, feeds it through the three-stage working assembly and returns it to the main tank.

The circulation pump and inline homogenizer perform different duties: the pump provides product movement through the circuit, while the homogenizer applies high shear. Neither function replaces the main agitator’s role in distributing material within the vessel.

Siemens PLC and HMI provide the specified control platform. The delivered automatic sequence, ingredient-addition method and operator tasks should be documented in the agreed functional schedule.

Finished product leaves through the flush bottom valve. A separate discharge rotor pump is optional and should not be confused with the included circulation pump. SUS304 product-contact construction requires compatibility review against the actual ingredients, temperatures and cleaning chemicals.


Machine Configuration

The main assembly includes a jacketed and insulated vessel with a conical bottom, fixed dished top head, gate agitator, fixed paddles and PTFE wall scrapers. Integrated oil and water pots provide separate ingredient-preparation capacity.

The external processing circuit comprises the standard circulation lobe pump, three-stage inline homogenizer and return pipework. Product flows from the main-vessel bottom through the pump and homogenizer before returning to the tank.

The jacket connects to the selected electric-heating or optional steam arrangement and the approved cooling-water service. The vacuum system connects through the designated vessel ports.

Siemens PLC and HMI coordinate the supplied functions through the agreed program. The flush bottom valve serves the discharge arrangement, with a separate discharge rotor pump optional. The platform, guardrails and ladder provide access. Final drawings should identify circuit routing, valve positions, cleaning access and the selected seal-support services.


Key Features

  • A standard circulation lobe pump feeds the external homogenizing circuit.
  • Three-stage inline processing provides successive high-shear zones within the working assembly.
  • External return pipework connects the homogenizer outlet back to the main vessel.
  • Scraped bulk agitation complements the separate pump-fed emulsification stage.
  • Integrated oil and water pots support formulation-specific phase preparation.
  • Jacketed construction accommodates the selected heating and cooling duties.
  • Conical-bottom geometry directs material toward the lower vessel outlet.
  • A flush bottom valve provides a defined discharge connection.
  • Siemens PLC and HMI support the agreed automatic processing functions.

Applications

  • Sauce, Condiment & Food Paste


Working Principle

Production begins with ingredient preparation according to the approved formulation. The oil and water pots support separate preparation where required, while other ingredients may enter the main vessel through designated charging connections.

The gate agitator establishes bulk movement within the main tank. PTFE scrapers act along the vessel wall, and the jacket supplies the selected thermal duty. These functions help establish the product condition required for incorporation and emulsification.

The circulation lobe pump draws product from the bottom of the main vessel and feeds it to the external inline homogenizer. Material passes through three successive high-shear stages before returning through the circulation pipework to the tank.

The ingredient-addition sequence and rate must match the formulation and processing capability. The three-stage arrangement does not mean that every portion of the batch receives exactly three total treatments: material can circulate repeatedly, and its exposure depends on actual flow, mixing and operating duration.

Vacuum is applied during the stages defined by the process. The PLC program coordinates the supplied functions, while operators complete any separately identified charging, sampling or authorization tasks.

After the batch reaches its accepted condition, finishing additions and cooling proceed as required. Product leaves through the flush bottom valve, using a separate discharge rotor pump if selected. The circulation and discharge routes must follow the approved valve arrangement rather than being treated as interchangeable pathways.


Optional Upgrades & Configurations

CIP Cleaning System
Load Cell Weighing Systems
Flow Meter
Automatic Powder & Liquid Feeding pathways
Recipe Storage System
Data Recording System
Online pH & Viscosity Monitoring Recipe Storage System
Nitrogen Protection System
Remote Monitoring
Explosion Proof Configuration
Other Custom Requirements

Warranty24 MonthsPayment Terms40% T/T Deposit, 60% Balance Before Shipment (Alibaba Trade Assurance Available)
Lead Time15–20 Working DaysPackagingStandard Export Fumigation-Free Wooden Case


After-Sales & Technical Support

🔧 Common Problems

Possible observable symptoms include uneven product appearance, visible oil separation, persistent agglomerates, inconsistent sample texture, excessive foam, retained air or unexpected viscosity changes. Circuit-related observations may include weak or intermittent return flow, unusual pressure indications, abnormal lobe-pump or homogenizer noise, vibration, drive trips or leakage around a seal or connection. Operators may also observe difficulty reaching the intended vacuum condition, unexpected pauses in the automatic sequence, slow discharge or retained material after emptying. Cleaning may leave visible residue in valve areas, working-head components or part of the return route. These are potential observations rather than confirmed defects. Record the ingredient stage, batch quantity, temperatures, valve positions and operating settings when investigating a symptom.

🛠 Troubleshooting

Problem: Oil separation or uneven texture appears. Possible Cause: Ingredient preparation, addition conditions, circulation or shear exposure differ from the approved process. Recommended Solution: Review the batch record and sampling conditions. Assess the complete sequence before increasing speed or processing time.Problem: Return flow becomes weak or intermittent. Possible Cause: Incorrect valve routing, inadequate pump supply, changing viscosity or a circuit restriction. Recommended Solution: Review the approved operating route and product conditions. Stop and isolate the equipment before investigating restrictions.Problem: The lobe pump or homogenizer produces abnormal noise. Possible Cause: Unsuitable operating conditions, foreign material or a mechanical fault. Recommended Solution: Stop the affected circuit. Obtain qualified inspection before restarting or replacing components.Problem: Vacuum remains below the intended condition. Possible Cause: An open vent, incorrectly seated connection, foaming or a vacuum-system fault. Recommended Solution: Review accessible settings and product behavior. Arrange inspection of the sealing and vacuum assemblies.Problem: The automatic sequence pauses unexpectedly. Possible Cause: A required process condition, confirmation or operating permission is absent. Recommended Solution: Review the HMI message and agreed functional schedule. Correct the identified condition without bypassing protections.Problem: Residue remains after cleaning. Possible Cause: Cleaning routing or access does not reach the affected surfaces. Recommended Solution: Review the approved route through the pump, homogenizer and return pipework before repeating cleaning.

🧼 Cleaning Method

1. Recover the remaining product through the approved discharge arrangement. 2. Bring the system to the safe temperature specified for cleaning access. 3. Equalize vessel pressure through the approved procedure before opening connections. 4. Isolate energy sources under the site's lockout procedure before manual access. 5. Configure the approved cleaning route through the main vessel and external circuit. 6. Pre-rinse the product-contact pathway with a medium suitable for the residue. 7. Apply the approved cleaning agent under the specified cleaning conditions. 8. Clean the main vessel through the supplied spray provision using the approved supply arrangement. 9. Clean the circulation lobe pump according to its component instructions. 10. Clean the three-stage inline homogenizer through its approved cleaning or service-access method. 11. Clean the return pipework through the designated route. 12. Clean the auxiliary pots according to their individual procedures. 13. Clean designated detachable valve and connection components separately where required. 14. Rinse until the specified cleaning-agent acceptance criteria are met. 15. Sanitize the system when the validated product-changeover procedure requires it. 16. Inspect accessible areas for retained residue before reassembly. 17. Release the system after the required cleaning checks are complete.

📋 Maintenance

1. Isolate the system under the approved lockout procedure before preventive maintenance. 2. Equalize vessel pressure through the approved method before opening service connections. 3. Confirm a safe product-contact temperature before accessing components. 4. Inspect the gate agitator and fixed paddles for visible damage. 5. Examine PTFE scrapers for wear, deformation or damaged attachments. 6. Inspect lobe-pump wetted components during approved service access. 7. Inspect the three-stage working assembly according to the homogenizer service instructions. 8. Check the installed mechanical seals for leakage or deterioration. 9. Maintain seal-support services according to the selected component documentation. 10. Examine product-contact gaskets for damage or chemical attack. 11. Inspect circulation pipework and supports for visible deterioration. 12. Service the vacuum pump according to its manufacturer's schedule. 13. Inspect accessible heating and cooling connections for leakage. 14. Arrange qualified inspection of electrical terminals and protective devices. 15. Verify process instruments under the site's approved checking procedure. 16. Verify the supplied stop functions and operating protections through the approved test method. 17. Record maintenance findings against the machine and component identification.

⚙️ Installation

1. Review the approved general arrangement and circulation drawings before preparing the site. 2. Verify the delivery route against the transport envelope and handling requirements. 3. Obtain approval of the floor and supports for the complete operating loads. 4. Inspect the delivered equipment for visible transport damage. 5. Position the assemblies using the manufacturer's designated lifting arrangement. 6. Level the supports according to the installation instructions. 7. Secure the equipment according to the approved support design. 8. Assemble the platform access structure according to the supplied drawings. 9. Connect the main-vessel outlet to the circulation lobe pump. 10. Connect the pump discharge to the three-stage inline homogenizer. 11. Connect the homogenizer outlet to the approved main-vessel return point. 12. Connect the selected heating and cooling services. 13. Connect required vacuum-pump and mechanical-seal support services. 14. Connect the regulated compressed-air supply according to the pneumatic schedule. 15. Install any separate optional discharge pump according to its instructions. 16. Arrange electrical connection by qualified personnel using the final wiring documentation. 17. Verify protective earthing before electrical commissioning. 18. Commission the supplied functions against the approved control schedule. 19. Perform the approved liquid test of circulation and connected services. 20. Document the representative-product trial against the agreed acceptance criteria before routine production.

🔩 Spare Parts

Three-Stage Inline Homogenizer Rotor and Stator Service Set
Inline Homogenizer Mechanical Seal Assembly
Circulation Lobe Pump Mechanical Seal Kit
Circulation Lobe Pump Rotor Set — Match the Installed Pump
Circulation Lobe Pump Cover and Rotor Seal Kit
PTFE Scraper Blade Set
Product-Contact O-ring Seal Kit
Circulation Pipe Connection Gasket Set
Flush Bottom Valve Seal Kit
Manway and Sight Glass Gasket Set
Electric Heating Element — For the Electric-Heating Configuration
Rotary Shaft Oil Seal — Where Fitted
Drive Bearing Set — Match the Installed Bearing Specification
Vacuum Pump Service Kit — Match the Installed Pump Type
Optional Discharge Pump Service Kit — Where Supplied

Why Choose This Machine

  • Defined external processing route: The included circulation pump and return pipework establish a reviewable circuit from the vessel through the inline homogenizer and back.
  • Separate pumping and shearing duties: Product movement and high-shear processing are assigned to distinct components, allowing their operating relationship to be assessed against the actual formulation.
  • Complementary vessel mixing: Gate agitation and scraping address bulk movement and the wall region while the external system processes the circulating stream.
  • Integrated phase preparation: Oil and water pots support recipes requiring separate preparation without assuming one universal ingredient sequence.
  • Coordinated control platform: Siemens PLC and HMI provide the specified basis for the agreed automatic functions and operator interface.
  • Separate discharge selection: The optional discharge pump can be matched to the finished product and receiving equipment without being confused with the standard circulation pump.

Frequently Asked Questions

It combines a vacuum-capable main vessel, scraped agitation, separate oil and water pots, a standard circulation lobe pump and a three-stage external inline homogenizer. Its selection should reflect the complete formulation route, not only the 300L working capacity or the number of homogenizing stages.
Yes. The circulation lobe rotor pump is standard. The confirmed route is main-vessel bottom, circulation pump, three-stage inline homogenizer and return to the main tank. The quotation should identify the pump model, wetted materials, operating limits and its relationship with the homogenizer controls.
No. A separate discharge rotor pump is optional. It serves finished-product transfer and should be selected around viscosity, receiving height, transfer distance and the next operation. Do not treat the included circulation pump as proof that an independent discharge pump is supplied.

Installation Requirements

Use the final general arrangement drawing to plan the complete vessel, auxiliary pots, platform and external processing circuit. The listed dimensions are 2100 × 1500 × 2200 mm. Allow additional space for charging, service access, pump maintenance and removal of inline homogenizer components.

The listed machine weight is 1500 kg. Assess floor and support requirements using the complete operating loads, including product in the main vessel, auxiliary pots and circulation circuit. Calculate material mass from the actual densities.

Confirm the electrical supply against the final heater, agitator, homogenizer, circulation-pump, vacuum-pump and control-panel schedule. The listed total power is 22 kW. Qualified personnel should determine protection, cable sizing and earthing from the approved load schedule.

Provide the selected heating and cooling services with defined operating conditions. Optional steam heating requires an engineered supply, regulation and condensate arrangement. The 0.3 MPa jacket design pressure is not a product-vessel pressure rating.

Provide compressed air at the specified 0.4–0.8 MPa supply range for the included pneumatic functions. Confirm air quality, consumption and regulation from the final schedule.

Define vacuum-pump and mechanical-seal support services using the selected component documentation. Provide cleaning-water access, drainage and access to the entire circulation route. Include any optional discharge pump or chiller in the layout and utility assessment.


Technical Buyer's Handbook & Deep Insight

Who the 300L Vacuum Mayonnaise Emulsifying Machine Suits

This model is intended for manufacturers who need a coordinated batch vessel and pump-fed external emulsification circuit for compatible mayonnaise, dressing and sauce products. Its distinguishing features are the three-stage inline homogenizer, standard circulation lobe pump, conical-bottom vessel and separate preparation pots.

Consider the complete processing requirement before choosing the machine. A mayonnaise emulsion, a low-fat dressing and a ketchup formulation may place different demands on ingredient hydration, thermal preparation, circulation and finishing.

The related mayonnaise production line equipment guide provides broader planning context. This product page should be used to assess whether the specific 300L configuration matches that process.

Define the Pump-Fed Circulation Route in the Order

The confirmed route is main-vessel bottom, circulation lobe pump, three-stage inline homogenizer and return pipework to the main tank. The circulation pump is standard equipment.

Obtain a drawing identifying the suction route, pump, homogenizer, return connection and valve positions. Include the operating routes used during ingredient incorporation, normal recirculation, discharge and cleaning.

Actual flow depends on the product, pump, working-head assembly and circuit resistance. Neither pump presence nor homogenizer rpm establishes a circulation rate.

The controls should coordinate the pump and homogenizer within their approved conditions. Confirm how the supplied arrangement addresses low product supply, restricted flow and other operating limits identified by the component manufacturers.

Understand What Three Homogenizing Stages Establish

The three-stage specification identifies successive working zones within the inline unit. It does not mean three complete batch passes, three independent machines or a guaranteed threefold improvement over a single-stage head.

Ask for the actual stage arrangement and the working geometry proposed for the product. The required shear exposure should follow the accepted emulsion or dispersion result.

In a recirculating batch, some material may return through the unit before other regions of the vessel have experienced equivalent treatment. Bulk agitation, flow and processing duration therefore remain important.

If pass count is a process requirement, agree how it will be evaluated. Otherwise, define a product endpoint supported by a documented sampling method.

Check Oil-Phase Capacity Before Approving the Recipe

The oil pot is listed at 150L and the water pot at 240L. These figures should be reviewed against the actual formulation rather than treated as proof that every 300L mayonnaise batch can be prepared in one charge.

Compare the required oil quantity with the oil pot’s confirmed usable volume. A formulation containing a large oil fraction may require an approved staged supply or a different preparation arrangement. Do not assume the listed pot capacity can be exceeded.

For the water phase, identify the initial liquid available for ingredient incorporation and any later additions. The two auxiliary capacities should not be summed to calculate the main vessel’s batch size.

Confirm preparation temperature, agitation and transfer provisions for each pot separately.

Match Oil Addition to Emulsion Development

Ingredient addition is part of the emulsification method, not merely a charging task. The sequence must allow the selected emulsifying and thickening ingredients to function as intended.

Define where oil enters, how its addition is controlled and how the operator or program responds as the batch develops. The presence of an oil pot does not establish automatic metering or a particular injection location.

During trials, record ingredient quantities, addition sequence, circulation settings and the resulting product condition. Do not use a successful water-only circulation test as evidence that the system can incorporate the required oil phase.

Validate the 100–300L Working Range

The main vessel has a 360L total capacity, 300L working capacity and 100L listed minimum batch. Keep these limits separate during purchasing and production planning.

At 100L, review agitator engagement, pump supply and the relationship between circuit volume and material remaining in the tank. At 300L, assess bulk movement and the required addition allowance.

Specify the sampling locations and product checks used to assess uniformity. Surface appearance alone is insufficient to establish the condition of the complete batch.

For earlier development work, the 5L laboratory circulation vacuum emulsifier is a specific smaller platform to evaluate. Its results require production-scale assessment rather than direct copying of rpm and processing time.

Compare Different External-Circulation Architectures

The 1000L PLC external circulation emulsifying mixer provides a useful configuration comparison, although it serves a different batch scale and application range.

Selection point300L mayonnaise system1000L external-circulation system
Working capacity300L1000L
High-shear arrangementExternal three-stage inline homogenizerBottom-entry homogenizer with external return circuit
Circulation driveStandard separate lobe pumpHomogenizer-driven; additional circulation pump optional
Oil and water pots150L oil / 240L water500L oil / 800L water

These are architecture and capacity differences, not comparative performance results. “External circulation” does not identify one universal equipment layout.

Identify Sauces That Do Not Need the Complete Emulsifying System

Some sauces require heated blending and wall scraping without the vacuum and inline homogenizing stages. For that different duty, the 500L movable jacketed steam mixing tank with scraper is a specific alternative to review.

Conversely, a product requiring a defined emulsion should not be assigned to a scraper tank simply because it can heat and mix. Select the functions needed for the product before deciding on capacity.

Products containing pieces also require special attention. Passing material through a high-shear circuit may conflict with a requirement to preserve ingredient structure. Define the permitted processing route for those formulations.

Treat the Conical Bottom as a Geometry Choice, Not a Recovery Guarantee

The conical bottom directs material toward the lower outlet, while the flush bottom valve defines the supplied discharge connection. Actual recovery depends on product flow, temperature, outlet geometry and the connected route.

Review retained material in the circulation pump, homogenizer and return pipework as well as the vessel. A readily drained main tank does not establish an empty external circuit.

The guide to product recovery and manufacturing waste reduction provides further context for evaluating the complete pathway.

Separate Circulation-Pump Duty from Discharge-Pump Duty

The standard lobe pump serves the processing loop. A separate discharge rotor pump is optional and must be identified independently in the quotation.

Specify finished-product viscosity, receiving height, transfer distance and handling requirements before selecting that pump. The pump selection guide for cosmetic, food and pharmaceutical processing provides a framework for this assessment.

If the supplier proposes using a shared route or component for another duty, obtain an explicit drawing and operating procedure. Do not infer that function from the standard circulation arrangement.

Include the Full Circuit in Cleaning and Changeover

The specified CIP spray ball is one cleaning provision within the vessel. The complete cleaning method must also address the lobe pump, three-stage homogenizer, return circuit, outlet valve and auxiliary pots.

The guide to CIP spray balls and complete cleaning-system requirements explains why spray provision alone does not establish a validated automatic cycle.

Identify the cleaning route, valve positions, return arrangement and components requiring separate access. The guide to cleaning dead corners in process equipment can support the inspection plan.

Where products introduce different allergens or sensitive ingredients, establish the changeover acceptance criteria for the actual factory. Do not rely on visual cleanliness alone where the product requirements demand further checks.

Coordinate Filling with the Product’s Final Condition

The finished batch needs a defined route to holding or packaging. Include the effect of any waiting period and transfer method in the product assessment.

A double-head servo rotor pump filler with agitator hopper is a specific downstream option to evaluate for compatible products. Confirm filling temperature, viscosity, container requirements and the intended use of hopper agitation.

Daily output depends on the complete sequence: phase preparation, charging, emulsification, thermal stages, quality checks, discharge and cleaning. The 300L working capacity does not establish a fixed number of batches per shift.

Evaluate the Complete Operating Cost and Automation Scope

The Siemens platform should be specified through its delivered functions. Define the automatic sequence, operator confirmations, pump coordination and required indications. Add recipe storage, dosing or electronic records only where explicitly agreed.

The listed 22 kW total power requires a final load schedule identifying the included heater, motors, pumps and controls. Do not derive missing component ratings by subtraction.

Compare cleaning resources, retained product, pump and homogenizer maintenance, utilities and operator time alongside the purchase price. The machinery total cost of ownership guide provides a broader purchasing framework.

Prepare a Model-Specific Purchase Checklist

  • Define the actual mayonnaise, dressing, ketchup or sauce formulation.
  • Provide viscosity with temperature and measurement conditions.
  • Check phase quantities against the auxiliary pots’ usable volumes.
  • Specify oil-addition location, control method and sequence.
  • Approve the main-vessel, lobe-pump, homogenizer and return-circuit drawing.
  • Obtain the three-stage working-head specification and operating limits.
  • Include both minimum and routine batch sizes in the application assessment.
  • Define the delivered automatic functions and operator tasks.
  • Review SUS304 and seal compatibility with ingredients and cleaning chemicals.
  • Separate the standard circulation pump from the optional discharge pump.
  • Agree cleaning coverage, sampling methods and product acceptance criteria.

StriversMachinery manufactures core equipment in-house and sources complementary equipment from long-term partner manufacturers, taking responsibility for complete production line integration and delivery. For this model, the agreed scope should connect phase preparation and pump-fed emulsification with cleaning, discharge and the selected packaging process.


Ready to Get a Quote?

Contact our team directly for pricing, customization options, and delivery timelines.

💬 WhatsApp Us Now
This field is required.
This field is required.
If you are not sure, just tell us what products do you produce.
This field is required.
Please check the box to confirm you agree to our Privacy Policy and Cookie Policy before submitting.