Stainless Steel Air Operated Double Diaphragm Pump with Threaded Ports | 1/2 Inch
This 1/2 inch stainless steel diaphragm pump uses compressed air to drive two diaphragms for liquid transfer through threaded connections. The supplied flow range is 0–3.36m³/h, with the working output selected around the liquid and piping duty. The specified head is 84m. SUS304 and SUS316L form the listed metal construction. For chemical liquids or paint transfer, the diaphragm and other wetted materials are chosen around the actual product, including the cleaning fluid.
- Flow Rate (m³/h)
- 0–3.36
- Pump Type
- Pneumatic Double Diaphragm Pump (AODD)
- Max Working Pressure (MPa)
- 0.86
- Construction Material
- SUS304 & SUS316L Combined
Product Overview
A transfer pump may cycle quickly while the receiving tank fills slowly. With an air-operated diaphragm pump, the first questions are how liquid reaches the inlet and how much air reaches the pump while it runs. A higher pressure setting alone may leave the cause untouched.
This stainless steel AODD pump provides a pneumatic transfer arrangement with 1/2 inch threaded fluid connections. Compressed air moves the diaphragms; the drive does not need an electric motor at the pump. The reference unit is floor-standing and weighs 10kg.
Its supplied liquid-viscosity reference is below 10,000cP. That figure helps screen an application, but the required flow still needs to be assessed at the actual product temperature and discharge conditions. Thick material in a long suction hose can make a nominally suitable pump slow to fill its chambers.
Material selection is another part of the order. The metal construction is listed as a combination of SUS304 and SUS316L. Diaphragms and valve components have their own material requirements. Chemical concentration and cleaning conditions belong in that selection, rather than treating stainless steel as a universal compatibility statement.
Within the process support equipment range, this model serves liquid movement between process stages. Start with the transfer duty and develop the connections around it.
Technical Specifications
| Construction Material | SUS304 & SUS316L Combined |
|---|---|
| Pump Type | Pneumatic Double Diaphragm Pump (AODD) |
| Flow Rate (m³/h) | 0–3.36 |
| Operating Head Range (m) | 84 |
| Max Working Pressure (MPa) | 0.86 |
| Applicable Viscosity (cps) | <10,000 |
| Connection Standard | Threaded |
| Air Pressure | 0.4–0.8 MPa |
| Drive Type | Pneumatic |
| Installation Type | Floor-Standing |
View All SpecificationsShow Fewer Specifications
| Automation Level | Fully Automatic |
|---|---|
| Machine Weight (kg) | 10 |
Ordering & Delivery
| Warranty | 24 Months | Payment Terms | 40% T/T Deposit, 60% Balance Before Shipment / Other payment terms available upon request |
| Lead Time | In Stock | Packaging | Standard Export Fumigation-Free Wooden Case, Fumigation-Free Wooden Pallet, Plastic Pallet, Metal Pallet, Custom Packaging Available |
| OEM / ODM Service | 100% Customizable / Engineering Support Available | ||
Machine Configuration
| Component | Specified arrangement |
|---|---|
| Pump principle | Air-operated double diaphragm pumping, using compressed air as the drive source. |
| Fluid connections | 1/2 inch nominal size with threaded connections; thread form specified for the order. |
| Metal construction | Listed SUS304 and SUS316L combination; component allocation follows the approved materials schedule. |
| Liquid-side assembly | Two diaphragm chambers with inlet/discharge check-valve functions; wetted service materials matched to the selected build. |
| Air distribution | Alternates compressed air between the diaphragm sides during operation. |
| Mounting arrangement | Floor-standing pump with a listed reference weight of 10kg. |
| Air supply reference | 0.4–0.8MPa; pressure regulation and air delivery sized for the intended operating point. |
| Head specification | 84m; operating flow selected against the required transfer duty. |
Key Features
- Compressed air drives the pump without an electric motor at the transfer point.
- Double diaphragm action draws liquid into one chamber while the other discharges.
- Threaded 1/2 inch connections provide the stated fluid-line interface.
- Pumping action uses no rotating shaft seal between the liquid path and drive.
- Air adjustment changes the pumping rate within the limits of the selected duty.
- SUS304/SUS316L metal construction provides a basis for project-specific material selection.
Applications
Suitable Products
Working Principle
The air distribution system sends compressed air alternately to opposite sides of the diaphragm assembly. As one diaphragm moves through its discharge stroke, the other chamber draws liquid through its inlet. Check-valve action controls which way the liquid travels.
On the next stroke, the air distribution changes sides. The chamber that filled now discharges, while the other draws in the next volume. Repeated strokes move liquid from the source through the pump to the receiving equipment.
The suction path must let the chambers fill. An air leak at a connection, restricted inlet or unsuitable suction lift can interrupt liquid supply even while the air side continues cycling. The discharge path then determines how much resistance the pump has to work against.
Air adjustment changes the operating behavior, but delivered flow also follows the liquid properties and connected system. Commissioning therefore starts with a controlled air setting and the intended product path. The selected operating point should deliver useful liquid flow without relying on rapid cycling that produces little extra transfer.
During shutdown or service, the air supply and liquid pressure are isolated through the approved procedure. The pump’s automatic reciprocating action is separate from any tank-level or batch-stop control that a complete system may require.
Why Choose This Machine
A pneumatic diaphragm transfer pump is worth assessing where plant air is available and the task is to move compatible liquid between vessels or into another process stage. It avoids placing an electric drive motor at the pump, while keeping the transfer duty tied to the available air service.
The purchase still needs an operating point. The listed 3.36m³/h upper flow reference does not describe every product below the viscosity limit, and the required discharge pressure can change the working output. A proposal based on the actual hose route is more useful than one based only on nominal port size.
For chemical or coating work, the choice of diaphragms and valve materials gives the specification a clear focus. Those components need to suit the product and cleaning cycle together. If the receiving process needs a steady, closely controlled feed, assess pulsation before settling on this arrangement. The best fit is the pump that meets that receiving task with an acceptable operating and service routine.
Optional Upgrades & Configurations
Integration Compatibility
Installation Requirements
Specified air-supply range: 0.4–0.8MPa.
Mounting arrangement: floor-standing, with service access and independently supported connections.
Listed pump weight: 10kg.
Fluid interfaces: nominal 1/2 inch threaded connections; thread form agreed for the order.
Process connections: compatible suction and discharge lines sized around the required duty.
Air service: regulated supply with the delivery capacity required at the operating point.
Exhaust arrangement: selected for the liquid and assessed installation conditions.
Custom Requirements
Provide viscosity at the actual pumping temperature. If the material thickens during storage, describe the condition at startup as well as during normal transfer.
State the flow you need at the receiving equipment and its pressure requirement. Include the hose length and rise so the duty can be assessed beyond the catalog flow figure.
Show where the pump sits relative to the source liquid level. Include the lowest operating level and the pickup arrangement, since suction conditions change as a vessel empties.
Describe any solids, including particle size and whether they are hard, abrasive or prone to settling. The port size alone is not a solids-passage rating.
Specify the mating thread standard and provide the site's available air pressure while equipment is running. Air delivery capacity is needed to select a working operating point.
View All Custom Requirements Show Fewer Requirements
Frequently Asked Questions
What is this 1/2 inch stainless steel diaphragm pump used for?
What does AODD mean?
Does the pump need an electric motor?
Is the whole pump made from 316L stainless steel?
What flow is listed?
View All FAQs (17)Show Fewer FAQs
Can it pump liquids below 10,000cP?
How much air pressure is specified?
Are the threads NPT or BSP?
Can it self-prime?
Can it run dry without damage?
Can it handle liquid with particles?
Is this a sanitary food pump?
Is pneumatic drive enough for a hazardous-area application?
Why does fast cycling sometimes produce little liquid?
Can it provide a smooth feed to downstream equipment?
What information is needed for a quotation?
What support is available?
Ready to Get a Quote?
Contact our team directly for pricing, customization options, and delivery timelines.
💬 WhatsApp Us NowRecommended Accessories & Utilities
After-Sales & Technical Support
Common Problems
Operating symptoms can include rapid cycling with low delivery, delayed priming or a change in flow as the source vessel empties. The stroke may become irregular, or air may continue exhausting without useful liquid movement. Connections can show seepage, while the discharge hose may move more than expected during pumping. A new product or cleaning cycle may be followed by a shorter service life for diaphragms or valve parts. Liquid at the exhaust is a distinct fault requiring the pump to be stopped and isolated. Record the liquid condition and source level alongside the air setting so the symptom can be compared with the accepted operating point.
Troubleshooting
Problem: The pump cycles quickly but liquid flow remains low.
Possible Cause: Restricted suction, air entering the inlet line, insufficient chamber filling or changed product viscosity.
Recommended Solution: Review the source level and inlet path before increasing air. Inspect hose restrictions and connections, then assess the operating setting with the actual liquid.
Problem: The pump will not cycle or runs irregularly.
Possible Cause: Inadequate air delivery, a restricted exhaust or a fault in the air distribution assembly.
Recommended Solution: Examine the running air supply and accessible exhaust path. Isolate the system before internal inspection under the supplied service instructions.
Problem: Liquid appears at the air exhaust.
Possible Cause: A diaphragm or its associated assembly may have failed.
Recommended Solution: Stop the pump, isolate air and liquid pressure, and contain the discharge through the site's product-handling procedure. Inspect the diaphragm assembly before restart.
Problem: Transfer falls as the source vessel empties.
Possible Cause: The inlet draws air or the changing suction condition makes chamber filling more difficult.
Recommended Solution: Examine pickup submergence and the liquid path at the lower level. Assess pump position and inlet restrictions against the required transfer duty.
Problem: Connections leak after a period of operation.
Possible Cause: Unsuitable thread engagement, incompatible seals or movement loading the connections.
Recommended Solution: Isolate and depressurize before inspecting the joint. Correct the connection and pipe support using the installed equipment instructions.
Problem: Diaphragms or valve parts deteriorate early.
Possible Cause: Chemical incompatibility, temperature exposure or abrasive service outside the selected material's suitability.
Recommended Solution: Compare the complete product and cleaning conditions with the parts schedule. Establish the cause before replacing parts with the same specification.
Cleaning Method
Recover product through the approved process procedure. Isolate the compressed-air supply and relieve retained liquid pressure before opening a connection or dismantling the pump.
Select the cleaning fluid against the pumped material and every wetted component. The metal grade alone does not determine compatibility with the diaphragms or valve parts. Follow the installed pump instructions for flushing or dismantling, with a contained route for recovered liquid.
Clean the fluid connections, manifolds and pumping chambers. Where the procedure requires access to valve components, inspect their contact areas for residue or retained particles before reassembly. Do not force an obstructed flow path by applying more air pressure.
Keep cleaning liquid out of air-side components unless the supplied instructions permit the method. External wipe-down and liquid-path cleaning are separate tasks.
After cleaning, inspect the parts and reassemble using the prescribed fastener sequence and settings. Verify containment and operation through the approved return-to-service procedure. Hygiene-sensitive work needs its own cleanliness release; the supplied information does not establish a validated CIP or sterilization cycle.
Maintenance
Record changes in useful flow together with the liquid condition and air setting. Faster cycling with less transfer can point to a developing supply problem before it becomes a diaphragm replacement job.
Inspect accessible fluid connections for leakage and examine hose support for movement that loads the pump ports. Review the liquid-side service parts for wear when the maintenance procedure calls for opening the assembly. Select replacements against the installed model and wetted-material schedule.
Keep the air supply and exhaust arrangement in serviceable condition. Moisture or a restriction on the air side can cause irregular operation. Follow the supplied air-system instructions for lubrication requirements rather than adding an oiler as a default practice.
Diaphragm condition deserves attention when the product or cleaning chemistry changes. Retain a record of the material fitted and the reason for replacement. No fixed replacement interval is established by the provided data.
After service, complete the prescribed containment and operating checks before returning the pump to its process connection. A fault involving liquid at the exhaust requires investigation of the diaphragm assembly rather than a setting adjustment.
Installation
Place the floor-standing pump on a suitable support with access to the air distribution assembly and liquid-side service areas. Position it near the source where the process layout permits, keeping the suction route short and avoiding unnecessary restrictions.
Specify the thread form before connecting the fluid lines. Support the pipework independently so it does not load the pump ports. The suction hose must suit the liquid and suction duty, including the possibility of collapse or air entry at a connection.
Connect a regulated compressed-air service sized for the required operating point. Arrange air isolation for service and keep the exhaust route suitable for the handled liquid, including the consequences of a diaphragm failure. Any hazardous-area duty requires an assessed installation and the appropriate equipment specification.
Introduce the intended liquid through the approved startup procedure at a controlled air setting. Observe priming and measure useful delivery at the required discharge condition. Include the source level expected near the end of a transfer, then record the accepted operating setup.
Optional Spare Parts
Optional spare parts are quoted separately. Any included wear-parts kit is listed in the order confirmation.
Diaphragm Set, maintenance candidate matched to the selected material and pump model
Liquid Check-Valve Service Parts, maintenance candidates matched to the installed valve design
Wetted Seal or Gasket Kit, maintenance candidate selected from the final parts list
Air Distribution Service Kit, maintenance candidate matched to the supplied air system
Technical Buyer’s Guide
Recommended Machines
Get Your Download Link