Inner Plug Press Machine | Pneumatic Stopper Inserting Machine for 5-25L Jerry Cans, HDPE Drums and Plastic Bottles
The Jerry Can Inner Plug Pressing Machine is a pneumatic station for seating separate inner plugs in compatible plastic containers before outer screw capping. A handwheel sets the pressing-head height, while a cylinder, solenoid valve and photoelectric sensor support the pressing sequence. The described 5–25L jerry-can arrangement shares the screw capper’s control system. Plug dimensions, container height and line interfaces can be customized for the project.
- Production Speed (BPM)
- 20-50
Product Overview
This station performs the inner-plug pressing step used on jerry cans and other plastic packages with a separate inner closure and threaded outer cap. It suits compatible HDPE containers used for products such as lubricants, detergents, coatings and chemicals, where the package design requires the plug to be seated before the outer cap is tightened.
The supplied assembly consists of a height-adjustment handwheel, pneumatic cylinder, pressing head, solenoid valve and photoelectric sensor. The head setup follows the container and plug geometry. The pneumatic stroke applies the pressing action, while the sensor and control sequence coordinate the station with container presentation.
In the described line, operators place the inner plugs manually and the pressing station shares the screw capper’s control system. The subsequent servo claw screw capping machine tightens the outer closure. Automatic inner-plug feeding is a separately customized function, not part of the manually loaded reference arrangement.
The representative application is approximately 5–25L plastic jerry cans. Container volume is only one selection detail: the neck, plug profile, supporting structure and head access determine the actual fit. StriversMachinery can develop the tooling, height arrangement and required functions around the supplied packaging samples and factory layout.
Technical Specifications
| Production Speed (BPM) | 20-50 |
|---|---|
| Contact Material | SUS304 Stainless Steel |
| Machine Frame Material | SUS304 Stainless Steel Frame |
| Conveyor System | POM Slat Chain Conveyor / SUS304 Stainless Steel Chain (Optional) |
| Capping Method | Constant-Force Pneumatic Capping |
| Capping Principle | Inner Plug / Cork / Stopper Pressing |
| Capping Head/Heads | 1 |
| Cap Size Range (Ø=mm) | 10-100 |
| Bottle Diameter Range (mm) | 20-250 |
| Bottle Height Range (mm) | 50-350 |
View All SpecificationsShow Fewer Specifications
| Cap Absence Detection | Cap Absence Detection & Rejection Included |
|---|---|
| Pneumatic Brand | AirTAC |
| Cylinder Brand | Airtac |
| Photoelectric Brand | SICK |
| Voltage | Configurable to local grid (110V–480V, 50/60Hz, Single or 3-Phase) |
| Total Power (kW) | 0.2 |
| Air Pressure | 0.4–0.8 MPa |
| Drive Type | Electro-Pneumatic Combined |
| Installation Type | Floor-Standing |
| Automation Level | Fully Automatic |
| Electrical Components | Schneider / ABB / Siemens / Omron / Fuji /Mitsubishi (Optional) |
| Control System | PLC + HMI Touch Screen Control |
| Machine Dimensions(L*W*H)mm | 1000*300*1700 |
| Machine Weight (kg) | 50 |
Ordering & Delivery
| Warranty | 24 Months | Payment Terms | 40% T/T Deposit, 60% Balance Before Shipment (Alibaba Trade Assurance Available) |
| Lead Time | 15–20 Working Days | Packaging | Standard Export Fumigation-Free Wooden Case |
| OEM / ODM Service | 100% Customizable / Engineering Support Available | ||
Machine Configuration
| Component | Configuration and function |
|---|---|
| Pressing assembly | Single pneumatic pressing head for the approved inner-plug and neck combination. |
| Height setup | Handwheel adjustment to establish the pressing-head height for the selected container. |
| Actuation | AirTAC pneumatic cylinder with solenoid-valve control; air supply specified at 0.4–0.8MPa. |
| Container sensing | SICK photoelectric sensor for the agreed station-detection sequence. |
| Plug presentation | Manual inner-plug placement in the described reference line; automatic supply is separately customized. |
| Control integration | Shares the screw capper’s control system in this arrangement; the PLC/HMI interface belongs to the agreed shared control architecture. |
| Missing-plug response | The supplied specification lists closure-absence detection and rejection; the inner-plug sensing and response are defined in the station control sequence. |
| Construction | SUS304 frame and listed contact construction; pressing-tool contact profile selected for the plug. |
| Conveyor interface | Listed POM slat-chain arrangement, with SUS304 chain as an alternative; conveyor sections and supply boundaries follow the line layout. |
| Installation | Floor-standing station coordinated with the container-transfer arrangement. |
Key Features
- A dedicated pressing head seats the inner plug before outer-cap tightening.
- Pneumatic actuation provides the specified pressing movement through a cylinder and solenoid valve.
- Handwheel height adjustment establishes the head setup for the selected container.
- Photoelectric sensing supports the station’s agreed container-detection sequence.
- Shared controls coordinate the pressing station with the screw capper in the described line.
- Matched head tooling can accommodate the approved plug dimensions and contact profile.
- The floor-standing arrangement can be integrated with the selected conveyor layout.
- Automatic plug-supply requirements can be incorporated into a separately defined custom design.
Applications
Suitable Products
Working Principle
The container reaches the inner-plug station after the required upstream operation. In the described packaging line, staff place the plug at the container opening before the pressing stage. Its initial presentation must suit the neck and the approved seating method.
During format setup, the handwheel establishes the pressing-head height. The selected tooling is aligned with the plug and opening, and the container is supported in the approved operating position. Height setup, plug shape and container support work together; nominal container volume alone does not define the correct adjustment.
The photoelectric sensor supplies the detection input used by the shared control sequence. When the required operating conditions are met, the solenoid valve actuates the pneumatic cylinder. The pressing head moves into contact with the plug and seats it through the approved stroke. The cylinder then returns the head to its release position.
The station uses the agreed missing-closure detection and rejection response. This function is separate from verifying insertion depth, pressing force or leak performance; those checks must be defined for the actual package rather than inferred from the presence of a sensor.
The container proceeds to outer screw capping after the pressing step. This station does not rotate the outer cap or fill the container. Its control connection to the capper coordinates the specified operations, while manual plug supply remains an operator task unless automatic feeding has been added to the custom project.
Why Choose This Machine
- Addresses the inner closure directly. A dedicated pressing operation is appropriate when the package requires an inner plug before the outer screw cap, instead of relying on the outer cap to complete an unspecified seating action.
- Can fit an existing packaging route. The station can be developed around the conveyor and upstream/downstream equipment required by the project.
- Provides a defined format adjustment. Handwheel setup gives the selected container a deliberate head-height setting rather than treating all 5–25L packages as identical.
- Coordinates with outer-cap tightening. Shared controls suit the described line arrangement and allow the two distinct closure steps to be planned together.
- Supports a practical automation choice. Manual plug placement can remain part of the workflow, with a compatible automatic feeder developed when the required output and plug characteristics justify it.
- Tooling follows the package. Custom head geometry and supporting arrangements can be reviewed using actual plugs and necks, helping the specification address fit rather than container capacity alone.
Optional Upgrades & Configurations
Installation Requirements
Listed Station Power: 0.2kW.
Compressed-Air Supply Pressure: 0.4–0.8MPa.
Installation Type: Floor-standing station aligned with the approved conveyor layout.
Container Support: Stable support beneath the pressing position.
Control Interface: Shared with the screw capper in the described configuration.
Package Supply: Matching containers and manually presented inner plugs, unless automatic feeding is separately specified.
Access: Clearance for handwheel setup, plug loading, tooling changes and maintenance.
Cleaning: Compatible external cleaning method and suitable collection of cleaning waste.
Frequently Asked Questions
What does the Jerry Can Inner Plug Pressing Machine do?
Are inner plugs fed automatically in this arrangement?
Does this station have its own PLC and touchscreen?
How is the head height adjusted?
Does 5–25L define every compatible container?
View All FAQs (17)Show Fewer FAQs
What plug sizes are listed?
Is the station suitable for corks or external snap-on caps?
Does constant-force pneumatic pressing mean force is measured automatically?
How is correct plug seating accepted?
Does missing-plug detection verify insertion depth?
What causes an inner plug to tilt during pressing?
Can it run at 20–50 containers per minute with a 25L package?
Can outer-cap tightening be performed in the same line?
Is SUS304 the same specification as the filling machine’s SS316L?
Can the station be added to an existing conveyor?
What can be customized?
What support is available after delivery?
Ready to Get a Quote?
Contact our team directly for pricing, customization options, and delivery timelines.
💬 WhatsApp Us NowAfter-Sales & Technical Support
Troubleshooting
Problem: The plug is not fully seated.
Possible Cause: Incorrect head-height setup, an unsuitable plug/neck combination, poor support or insufficient air at the station.
Recommended Solution: Compare the package with approved samples and inspect the setup and supply. Restore the agreed conditions before changing pressure; do not exceed the specified air range.
Problem: The plug tilts or deforms during pressing.
Possible Cause: Poor initial placement, misalignment, an unsuitable tool profile or excessive action for the package.
Recommended Solution: Stop and inspect plug presentation, tooling and container position after safe isolation. Correct the setup rather than repeating a forceful stroke on a damaged package.
Problem: The cylinder moves slowly or irregularly.
Possible Cause: Restricted air supply, leakage, a valve problem or a mechanical obstruction.
Recommended Solution: Inspect accessible connections and the pressing path after the assembly has been secured. Have qualified personnel examine the pneumatic circuit if normal supply does not restore movement.
Problem: A presented container does not initiate the expected sequence.
Possible Cause: Sensor contamination or misalignment, incorrect presentation or an unmet shared-control condition.
Recommended Solution: Review the sensor and container position. Use the approved control procedure to identify the missing condition; do not bypass a required response.
Problem: The missing-plug response is inconsistent.
Possible Cause: An unsuitable sensing position, package variation or incorrect response timing.
Recommended Solution: Verify the function with agreed present/absent test samples. Review the sensor and shared-control setup before releasing the station for production.
Cleaning Method
1. Stop container supply through the shared control sequence.
2. Remove packages and loose plugs after the pressing movement has stopped.
3. Isolate electrical and pneumatic energy before reaching into the pressing zone.
4. Release stored air through the approved method.
5. Secure the pressing assembly against unintended movement.
6. Remove loose packaging debris and product residue from accessible surfaces.
7. Clean the pressing-head contact face using media compatible with its supplied construction.
8. Remove tooling for separate cleaning only where the service procedure requires it.
9. Clean container-support surfaces and adjacent conveyor guides.
10. Clean the photoelectric sensor window using its approved method.
11. Inspect the head profile and supporting areas for retained plug fragments or residue.
12. Dry the cleaned components as required before reassembly.
13. Refit removed parts according to the approved format setup.
14. Verify pressing and detection functions using the agreed first-off packages before restarting.
Keep cleaning liquids out of the shared control equipment, sensor connections and pneumatic components unless their supplied protection ratings permit the method. The pressing station is external packaging equipment, not a liquid-process CIP system. Select the cleaning method around the actual contact materials and factory hygiene procedure.
Maintenance
Isolate the electrical connection and compressed-air supply before maintenance. Release stored pneumatic energy and secure the pressing assembly before working beneath or around the head. Qualified personnel should perform pneumatic repairs, electrical work and changes to the shared control sequence.
Inspect the pressing head for damage, retained debris and changes to its contact profile. Compare the tooling with the approved plug sample and verify its mounting. A damaged face or loose connection can change how the plug is contacted even when the height setting has not changed.
Inspect the handwheel adjustment, guides and accessible fasteners for looseness or abnormal movement. Maintain lubrication only at the points and intervals required by the supplied component instructions. Do not introduce an unsupported oiling procedure into the pneumatic system.
Inspect the cylinder, solenoid valve, air lines and connections for leakage, damage or impaired movement. Maintain the air-service components actually included in the build. Keep the sensor window and accessible cables in good condition.
Review station alignment and support after any conveyor or container-format adjustment. Recheck the pressing result and missing-plug response after relevant maintenance. Record changes, service observations and replacement parts against the delivered build rather than applying a generic fixed replacement interval.
Installation
Position the floor-standing pressing station according to the approved conveyor layout. Provide access for manual plug placement, head-height setup, tooling removal and maintenance. Establish stable container support beneath the pressing action using the agreed installation arrangement.
Align the head with the intended neck position using representative containers and plugs. Set the handwheel height through the supplied setup procedure. Keep container handles and body variations clear of the pressing path, and preserve access to the sensing position.
Connect the station to the screw capper’s shared control system according to the approved wiring and interface documentation. The listed station power is 0.2kW; coordinate this reference value with the shared cabinet’s electrical schedule rather than assuming that it defines a separate complete control package.
Provide compressed air within the specified 0.4–0.8MPa range. Route air lines and cables away from moving containers and operator access. Complete the agreed conveyor and detection interfaces before commissioning.
Verify the permitted pressing sequence, sensor response and missing-plug action using the supplied procedure. Establish the setup with approved package samples and inspect seating before containers proceed to outer capping. Release the station only after the agreed first-off checks, then retain the format settings for the next changeover.
Optional Spare Parts
Optional spare parts are quoted separately. Any included wear-parts kit is listed in the order confirmation.
Replacement Inner-Plug Pressing Head
Pneumatic Cylinder Seal Kit