The Jerry Can Inner Plug Pressing Machine is a pneumatic station for seating separate inner plugs in compatible plastic containers before outer screw capping. A handwheel sets the pressing-head height, while a cylinder, solenoid valve and photoelectric sensor support the pressing sequence. The described 5–25L jerry-can arrangement shares the screw capper’s control system. Plug dimensions, container height and line interfaces can be customized for the project.

Production Speed (BPM)
20-50

Product Overview

This station performs the inner-plug pressing step used on jerry cans and other plastic packages with a separate inner closure and threaded outer cap. It suits compatible HDPE containers used for products such as lubricants, detergents, coatings and chemicals, where the package design requires the plug to be seated before the outer cap is tightened.

The supplied assembly consists of a height-adjustment handwheel, pneumatic cylinder, pressing head, solenoid valve and photoelectric sensor. The head setup follows the container and plug geometry. The pneumatic stroke applies the pressing action, while the sensor and control sequence coordinate the station with container presentation.

In the described line, operators place the inner plugs manually and the pressing station shares the screw capper’s control system. The subsequent servo claw screw capping machine tightens the outer closure. Automatic inner-plug feeding is a separately customized function, not part of the manually loaded reference arrangement.

The representative application is approximately 5–25L plastic jerry cans. Container volume is only one selection detail: the neck, plug profile, supporting structure and head access determine the actual fit. StriversMachinery can develop the tooling, height arrangement and required functions around the supplied packaging samples and factory layout.


Technical Specifications

Production Speed (BPM)20-50
Contact MaterialSUS304 Stainless Steel
Machine Frame MaterialSUS304 Stainless Steel Frame
Conveyor SystemPOM Slat Chain Conveyor / SUS304 Stainless Steel Chain (Optional)
Capping MethodConstant-Force Pneumatic Capping
Capping PrincipleInner Plug / Cork / Stopper Pressing
Capping Head/Heads1
Cap Size Range (Ø=mm)10-100
Bottle Diameter Range (mm)20-250
Bottle Height Range (mm)50-350
View All SpecificationsShow Fewer Specifications
Cap Absence DetectionCap Absence Detection & Rejection Included
Pneumatic BrandAirTAC
Cylinder BrandAirtac
Photoelectric BrandSICK
VoltageConfigurable to local grid (110V–480V, 50/60Hz, Single or 3-Phase)
Total Power (kW)0.2
Air Pressure0.4–0.8 MPa
Drive TypeElectro-Pneumatic Combined
Installation TypeFloor-Standing
Automation LevelFully Automatic
Electrical ComponentsSchneider / ABB / Siemens / Omron / Fuji /Mitsubishi (Optional)
Control SystemPLC + HMI Touch Screen Control
Machine Dimensions(L*W*H)mm1000*300*1700
Machine Weight (kg)50

Ordering & Delivery

Warranty24 MonthsPayment Terms40% T/T Deposit, 60% Balance Before Shipment (Alibaba Trade Assurance Available)
Lead Time15–20 Working DaysPackagingStandard Export Fumigation-Free Wooden Case
OEM / ODM Service100% Customizable / Engineering Support Available

Machine Configuration

ComponentConfiguration and function
Pressing assemblySingle pneumatic pressing head for the approved inner-plug and neck combination.
Height setupHandwheel adjustment to establish the pressing-head height for the selected container.
ActuationAirTAC pneumatic cylinder with solenoid-valve control; air supply specified at 0.4–0.8MPa.
Container sensingSICK photoelectric sensor for the agreed station-detection sequence.
Plug presentationManual inner-plug placement in the described reference line; automatic supply is separately customized.
Control integrationShares the screw capper’s control system in this arrangement; the PLC/HMI interface belongs to the agreed shared control architecture.
Missing-plug responseThe supplied specification lists closure-absence detection and rejection; the inner-plug sensing and response are defined in the station control sequence.
ConstructionSUS304 frame and listed contact construction; pressing-tool contact profile selected for the plug.
Conveyor interfaceListed POM slat-chain arrangement, with SUS304 chain as an alternative; conveyor sections and supply boundaries follow the line layout.
InstallationFloor-standing station coordinated with the container-transfer arrangement.

Key Features

  • A dedicated pressing head seats the inner plug before outer-cap tightening.
  • Pneumatic actuation provides the specified pressing movement through a cylinder and solenoid valve.
  • Handwheel height adjustment establishes the head setup for the selected container.
  • Photoelectric sensing supports the station’s agreed container-detection sequence.
  • Shared controls coordinate the pressing station with the screw capper in the described line.
  • Matched head tooling can accommodate the approved plug dimensions and contact profile.
  • The floor-standing arrangement can be integrated with the selected conveyor layout.
  • Automatic plug-supply requirements can be incorporated into a separately defined custom design.

Applications


Suitable Products

Primary packages: plastic containers with a separate inner plug and an outer screw cap.
Representative format: compatible HDPE jerry cans of approximately 5–25L.
Application examples: lubricant containers, detergent containers, coating containers and compatible chemical-product packages requiring inner-plug pressing.
Other packages: plastic bottles and containers with an approved plug/neck geometry and customized head-height arrangement.
Listed inner-closure diameter reference: 10–100mm, subject to the selected plug and pressing-tool profile.
Listed container-diameter reference: 20–250mm; shaped jerry cans require their actual body dimensions, neck location and support arrangement.
Closure task: inner-plug seating. Corks, outer press-on lids and screw caps are not assumed interchangeable with the specified plastic-container plug.
Flip-Top & Pop-Top;
Press / Snap / Friction-Fit
inner plug
Round, Square, Oval, Wide-Mouth Jar, Asymmetric/Shaped Bottle

Working Principle

The container reaches the inner-plug station after the required upstream operation. In the described packaging line, staff place the plug at the container opening before the pressing stage. Its initial presentation must suit the neck and the approved seating method.

During format setup, the handwheel establishes the pressing-head height. The selected tooling is aligned with the plug and opening, and the container is supported in the approved operating position. Height setup, plug shape and container support work together; nominal container volume alone does not define the correct adjustment.

The photoelectric sensor supplies the detection input used by the shared control sequence. When the required operating conditions are met, the solenoid valve actuates the pneumatic cylinder. The pressing head moves into contact with the plug and seats it through the approved stroke. The cylinder then returns the head to its release position.

The station uses the agreed missing-closure detection and rejection response. This function is separate from verifying insertion depth, pressing force or leak performance; those checks must be defined for the actual package rather than inferred from the presence of a sensor.

The container proceeds to outer screw capping after the pressing step. This station does not rotate the outer cap or fill the container. Its control connection to the capper coordinates the specified operations, while manual plug supply remains an operator task unless automatic feeding has been added to the custom project.


Product Video

Video not playing? Watch on YouTube.


Why Choose This Machine

  • Addresses the inner closure directly. A dedicated pressing operation is appropriate when the package requires an inner plug before the outer screw cap, instead of relying on the outer cap to complete an unspecified seating action.
  • Can fit an existing packaging route. The station can be developed around the conveyor and upstream/downstream equipment required by the project.
  • Provides a defined format adjustment. Handwheel setup gives the selected container a deliberate head-height setting rather than treating all 5–25L packages as identical.
  • Coordinates with outer-cap tightening. Shared controls suit the described line arrangement and allow the two distinct closure steps to be planned together.
  • Supports a practical automation choice. Manual plug placement can remain part of the workflow, with a compatible automatic feeder developed when the required output and plug characteristics justify it.
  • Tooling follows the package. Custom head geometry and supporting arrangements can be reviewed using actual plugs and necks, helping the specification address fit rather than container capacity alone.

Optional Upgrades & Configurations

Automatic inner-plug supply: develop a feeding and presentation arrangement matched to the plug, including a suitable vibratory feeder where appropriate.
Custom pressing head: adapt the contact profile and diameter to the actual plug and neck samples.
Height and container-format adaptation: develop the working range and access around the required packages.
Conveyor coordination: define station mounting, guides, transport interfaces and POM or selected SUS304 chain construction.
Control architecture: retain shared controls with the capper, or engineer a separately specified independent control arrangement when a standalone project requires it.
Detection response: define the missing-plug sensing, stop/rejection behavior and any additional package-inspection requirement.
Destination supply: configure electrical and pneumatic connections for the approved arrangement.
Other functional requirements can be incorporated into the custom project specification; they are not implied to be installed on the reference station.

Installation Requirements

Electrical Connection: Through the agreed shared control arrangement; supply follows the project wiring schedule.
Listed Station Power: 0.2kW.
Compressed-Air Supply Pressure: 0.4–0.8MPa.
Installation Type: Floor-standing station aligned with the approved conveyor layout.
Container Support: Stable support beneath the pressing position.
Control Interface: Shared with the screw capper in the described configuration.
Package Supply: Matching containers and manually presented inner plugs, unless automatic feeding is separately specified.
Access: Clearance for handwheel setup, plug loading, tooling changes and maintenance.
Cleaning: Compatible external cleaning method and suitable collection of cleaning waste.

Frequently Asked Questions

What does the Jerry Can Inner Plug Pressing Machine do?
It seats a separate inner plug in a compatible plastic container before the threaded outer cap is tightened. The reference station uses pneumatic actuation, a height-adjustment handwheel and photoelectric sensing, coordinated with the screw capper’s shared controls.
Are inner plugs fed automatically in this arrangement?
No. The described line uses manual plug placement. A suitable automatic feeder and presentation arrangement can be developed as part of customization. The pressing cylinder alone does not provide plug sorting or automatic supply.
Does this station have its own PLC and touchscreen?
The described station shares the screw capper’s control system. A PLC/HMI field in the specifications should not be interpreted as a separate dedicated cabinet supplied with this module. Independent controls can be engineered for a separately defined standalone requirement.
How is the head height adjusted?
A handwheel establishes the head height for the selected container. Set it using the approved package samples and supplied setup method. This is different from the cylinder’s operating stroke and should not be described as servo height adjustment.
Does 5–25L define every compatible container?
It describes the representative jerry-can application range. Actual compatibility depends on neck position, plug geometry, container height and support. Other plastic containers can be assessed through customization rather than accepted from nominal volume alone.
View All FAQs (17)Show Fewer FAQs
What plug sizes are listed?
The supplied reference gives a 10–100mm closure-diameter range. The selected pressing head must still match the plug’s full profile and intended seated position. Diameter does not establish compatibility with every closure inside that range.
Is the station suitable for corks or external snap-on caps?
This page describes inner plugs for compatible plastic containers. Cork insertion and external press-on closing need their own tooling and process assessment. A generic pressing-machine label does not establish those applications for this build.
Does constant-force pneumatic pressing mean force is measured automatically?
No such measuring system has been specified. The reference uses a pneumatic pressing action. Actual force depends on the engineered cylinder and air conditions; force measurement, monitoring or a numeric force tolerance must be separately defined if required.
How is correct plug seating accepted?
Use the packaging supplier’s intended assembled condition and agreed checks. These may include position, appearance and package-performance criteria relevant to the plug. Define the method before the trial instead of treating a completed cylinder stroke as proof of acceptance.
Does missing-plug detection verify insertion depth?
Not by itself. The listed absence-detection function and the pressing-quality check are separate. Any automatic assessment of seating depth, pressing force or package leakage is an additional requirement to specify during engineering.
What causes an inner plug to tilt during pressing?
Possible factors include initial placement, tool alignment, plug/neck variation or unsuitable support. Inspect those conditions with representative samples. Repeating the stroke or increasing pressure without identifying the cause can damage the package.
Can it run at 20–50 containers per minute with a 25L package?
The supplied number is a reference range without stated package conditions. Actual output depends on manual placement, container transfer and the approved pressing sequence. Establish the rate using the intended package and acceptance criteria.
Can outer-cap tightening be performed in the same line?
Yes. The pressing station can be coordinated with the servo claw screw capper, which performs the separate outer-cap tightening operation. Shared controls connect the workflow without making the two heads interchangeable.
Is SUS304 the same specification as the filling machine’s SS316L?
No. This station has SUS304 frame and listed contact construction. The filler has its own metallic liquid-contact specification. Keep packaging-tool contacts and the liquid flow path separate in the project materials schedule.
Can the station be added to an existing conveyor?
It can be assessed for that requirement. Provide conveyor height, neck position, package spacing, available support and control interfaces. The proposal should identify the supplied conveyor sections and any work required on the existing line.
What can be customized?
The head profile, plug dimensions, container-height arrangement, transport interfaces and required control functions can be developed around the project. Plug feeding and a standalone control package are separately specified changes to the reference arrangement.
What support is available after delivery?
Free remote technical support is available for setup guidance and troubleshooting. On-site installation, commissioning, training and maintenance can be arranged under the project agreement. Service parts and format tooling follow the delivered build.

Ready to Get a Quote?

Contact our team directly for pricing, customization options, and delivery timelines.

💬 WhatsApp Us Now
This field is required.
This field is required.
If you are not sure, just tell us what products do you produce.
This field is required.
Please check the box to confirm you agree to our Privacy Policy and Cookie Policy before submitting.

After-Sales & Technical Support

Troubleshooting

Problem: The plug is not fully seated.
Possible Cause: Incorrect head-height setup, an unsuitable plug/neck combination, poor support or insufficient air at the station.
Recommended Solution: Compare the package with approved samples and inspect the setup and supply. Restore the agreed conditions before changing pressure; do not exceed the specified air range.
Problem: The plug tilts or deforms during pressing.
Possible Cause: Poor initial placement, misalignment, an unsuitable tool profile or excessive action for the package.
Recommended Solution: Stop and inspect plug presentation, tooling and container position after safe isolation. Correct the setup rather than repeating a forceful stroke on a damaged package.
Problem: The cylinder moves slowly or irregularly.
Possible Cause: Restricted air supply, leakage, a valve problem or a mechanical obstruction.
Recommended Solution: Inspect accessible connections and the pressing path after the assembly has been secured. Have qualified personnel examine the pneumatic circuit if normal supply does not restore movement.
Problem: A presented container does not initiate the expected sequence.
Possible Cause: Sensor contamination or misalignment, incorrect presentation or an unmet shared-control condition.
Recommended Solution: Review the sensor and container position. Use the approved control procedure to identify the missing condition; do not bypass a required response.
Problem: The missing-plug response is inconsistent.
Possible Cause: An unsuitable sensing position, package variation or incorrect response timing.
Recommended Solution: Verify the function with agreed present/absent test samples. Review the sensor and shared-control setup before releasing the station for production.

Cleaning Method

1. Stop container supply through the shared control sequence.
2. Remove packages and loose plugs after the pressing movement has stopped.
3. Isolate electrical and pneumatic energy before reaching into the pressing zone.
4. Release stored air through the approved method.
5. Secure the pressing assembly against unintended movement.
6. Remove loose packaging debris and product residue from accessible surfaces.
7. Clean the pressing-head contact face using media compatible with its supplied construction.
8. Remove tooling for separate cleaning only where the service procedure requires it.
9. Clean container-support surfaces and adjacent conveyor guides.
10. Clean the photoelectric sensor window using its approved method.
11. Inspect the head profile and supporting areas for retained plug fragments or residue.
12. Dry the cleaned components as required before reassembly.
13. Refit removed parts according to the approved format setup.
14. Verify pressing and detection functions using the agreed first-off packages before restarting.
Keep cleaning liquids out of the shared control equipment, sensor connections and pneumatic components unless their supplied protection ratings permit the method. The pressing station is external packaging equipment, not a liquid-process CIP system. Select the cleaning method around the actual contact materials and factory hygiene procedure.

Maintenance

Isolate the electrical connection and compressed-air supply before maintenance. Release stored pneumatic energy and secure the pressing assembly before working beneath or around the head. Qualified personnel should perform pneumatic repairs, electrical work and changes to the shared control sequence.
Inspect the pressing head for damage, retained debris and changes to its contact profile. Compare the tooling with the approved plug sample and verify its mounting. A damaged face or loose connection can change how the plug is contacted even when the height setting has not changed.
Inspect the handwheel adjustment, guides and accessible fasteners for looseness or abnormal movement. Maintain lubrication only at the points and intervals required by the supplied component instructions. Do not introduce an unsupported oiling procedure into the pneumatic system.
Inspect the cylinder, solenoid valve, air lines and connections for leakage, damage or impaired movement. Maintain the air-service components actually included in the build. Keep the sensor window and accessible cables in good condition.
Review station alignment and support after any conveyor or container-format adjustment. Recheck the pressing result and missing-plug response after relevant maintenance. Record changes, service observations and replacement parts against the delivered build rather than applying a generic fixed replacement interval.

Installation

Position the floor-standing pressing station according to the approved conveyor layout. Provide access for manual plug placement, head-height setup, tooling removal and maintenance. Establish stable container support beneath the pressing action using the agreed installation arrangement.
Align the head with the intended neck position using representative containers and plugs. Set the handwheel height through the supplied setup procedure. Keep container handles and body variations clear of the pressing path, and preserve access to the sensing position.
Connect the station to the screw capper’s shared control system according to the approved wiring and interface documentation. The listed station power is 0.2kW; coordinate this reference value with the shared cabinet’s electrical schedule rather than assuming that it defines a separate complete control package.
Provide compressed air within the specified 0.4–0.8MPa range. Route air lines and cables away from moving containers and operator access. Complete the agreed conveyor and detection interfaces before commissioning.
Verify the permitted pressing sequence, sensor response and missing-plug action using the supplied procedure. Establish the setup with approved package samples and inspect seating before containers proceed to outer capping. Release the station only after the agreed first-off checks, then retain the format settings for the next changeover.


Optional Spare Parts

Optional spare parts are quoted separately. Any included wear-parts kit is listed in the order confirmation.

Replacement Inner-Plug Pressing Head
Pneumatic Cylinder Seal Kit


Technical Buyer’s Guide

This station serves a specific package structure: an inner plug is pressed into the neck before the outer screw cap is tightened. Its selection starts with the plug and container fit, then moves to supporting the package, presenting the plug and coordinating the station with the line. The representative 5–25L range is useful context, but the closure geometry determines the pressing task.

When the Jerry Can Inner Plug Pressing Machine Is the Right Step

Use a dedicated station when the packaging design calls for controlled seating of a separate inner plug. The outer screw cap has another function and should not be assumed to complete the required seating simply because it can be tightened over the neck.

First identify the package’s intended assembled condition. Obtain the plug and neck samples together, with drawings or supplier guidance where available. That gives the tooling review a real target instead of judging the operation only by whether the cylinder completes its movement.

Match the Head to the Plug and Neck Profile

The pressing tool must contact an appropriate part of the plug without interfering with the neck or deforming the closure. The listed 10–100mm diameter reference is only one dimension. Plug depth, flange shape, sealing features and material behavior can change the required contact profile.

Review samples from normal production rather than a single carefully selected set. A package that fits when aligned by hand outside the line may behave differently during repeated manual placement and conveyor presentation. The approved tooling should address that practical operating condition.

If several plugs share a similar diameter, do not assume they share one head. Agree which profiles use common tooling and which require a change part. Record the tool identity with the associated container and setup.

Treat Container Support as Part of the Pressing Setup

The pressing action needs an appropriate support path beneath the container. Body stiffness, base geometry, neck location and the intended filled condition influence how the package reacts. A broad jerry-can panel or offset opening can require a different support and alignment review from a smaller round bottle.

The 20–250mm container-diameter reference does not describe every shaped body. Provide the actual footprint, height, handle and neck position. Use those details to position the pressing station and check clearance through the full operating movement.

Set the handwheel height with the approved samples. The setup must allow the intended seating action without treating additional downward adjustment as a universal cure for a poor plug fit.

Plan Manual Plug Placement Before Selecting Automatic Feeding

The reference line uses manual inner-plug placement. Include that task when planning staff access, package presentation and sustainable output. The operator must be able to place plugs through the approved workflow without reaching into an active pressing zone.

If higher automation is required, evaluate the actual plug for feeding, orientation and presentation. A selected vibratory feeder may be suitable, but plug shape and handling behavior determine the arrangement. The feeder and station handover should be developed together.

Define how the line responds to a plug that is absent or incorrectly presented. Automatic supply does not remove the need for a clear detection and recovery procedure.

Specify Shared Controls and the Supply Boundary Clearly

This pressing station shares the screw capper’s control system in the described arrangement. Define the sensor inputs, valve action and agreed sequence within that architecture. A specification field naming PLC/HMI does not establish a separate cabinet for each station.

For a standalone installation, independent controls can be engineered as a separate requirement. For an existing line, review available interfaces and responsibilities before finalizing the wiring and operating method. The listed 0.2kW station power should be coordinated with that electrical scope.

Define conveyor supply in the same way. Distinguish an included station interface or section from the factory’s complete transport system, rather than assuming that a pictured conveyor establishes every site connection.

Keep Pneumatic Action Separate from Measured Force and Seating Quality

The station uses an AirTAC cylinder and solenoid-valve control with a specified air supply of 0.4–0.8MPa. The supply range is not a verified force at the plug. Actual pressing action depends on the cylinder design, conditions and setup.

The term constant-force pneumatic pressing must not be expanded into closed-loop force control or automatic force recording. If the package needs a measured insertion-force window, specify the measurement and acceptance requirement so it can be engineered.

Similarly, the listed missing-closure detection does not prove seating depth or package integrity. Agree how the pressed plug will be accepted, then decide whether visual checking, a defined gauge or additional inspection is required.

Compare Inner-Plug Pressing with Other Closing Tasks

The press-cap sealing machine handles a different closing task: pressing a compatible cap onto its package. The four-wheel screw capping machine uses another process again, tightening a threaded outer closure. Similar words such as cap or press should not obscure those functional differences.

OperationClosure roleAcceptance focus
This inner-plug stationSeats a separate inner closure before outer capping.Approved plug fit, seated position and package condition.
Press-cap closingPresses the specified external closure into its assembled position.Compatibility and closure engagement for that package.
Screw cappingTightens the threaded outer cap.Cap engagement and agreed tightening/package result.

This distinction keeps the current page focused on inner-plug selection rather than competing with every press-on or screw-capping product on the site.

Evaluate Output with the Intended Package and Operator Method

The listed 20–50 containers-per-minute range has no stated package or trial conditions. It does not establish a guaranteed rate for a filled 25L jerry can. Manual plug placement, package support, transfer and the accepted pressing result all affect sustainable operation.

State the required acceptable packs per shift and include normal interruptions and format changes. Trial the station at that operating basis. For a connected system, do not use this station’s separate reference rate as the complete filling-line output.

Agree Acceptance and the Integrated Packaging Route

Use the actual package samples and the intended incoming condition in the trial. Define seating acceptance with the packaging supplier and factory team before evaluating a demonstration.

  • Observe initial plug presentation and alignment.
  • Inspect the seated plug and container for damage or distortion.
  • Verify the agreed missing-plug response.
  • Review transition to outer-cap tightening.
  • Repeat relevant checks after a normal interruption and format change.

These are proposed evaluation topics, not completed test results. If the project includes filling, pressing, screw capping and labeling, review the jerry can filling, capping and labeling line for the coordinated arrangement. This page provides the inner-plug detail while the line page addresses the whole packaging process.

Send StriversMachinery the plug and container samples, output target, presentation method and required interfaces. The custom proposal can then define tooling, support, controls and additional functions together. Free remote technical support is available after delivery, with site services arranged under the project agreement.